overview versa 10 versa mini pcr setup nucleic acid liquid liquid extraction solid phase extraction envir. sample processing vial filling spot & microarray print applications reagents semi-automatic pipettor liquid handling system liquid handling system 8 channel pipettor viscometer comparision viscometer-smart viscometer-expert viscometer-premium thermostatic bath thermostatic bath safety cap safety cap safety waste cap safety waste cap level monitoring safety funnel built-in solution accessories
 
 
 
 
ROTATIONAL VISCOMETER-SMART SERIES         BIOCHEMICAL LABORATORY
 
 
Digital Viscometer deisgned for measuring viscosity
 
 

ROTATIONAL VISCOMETER - SMART SERIES

MODEL
MEASURING RANGE (cP)
SPEED (rpm)
NUMBER OF SPEEDS
SMART L
2 - 2,000,000
0.3 - 100
18
SMART R
100 - 13,000,000
0.3 - 100
18
SMART H
200 - 106,000,000
0.3 - 100
18
SMART L with temperature probe PT100
2 - 2,000,000
0.3 - 100
18
SMART R with temperature probe PT100
100 - 13,000,000
0.3 - 100
18
SMART H with temperature probe PT100
200 - 106,000,000
0.3 - 100
18
 
 
Optional Accessories:

MODEL SMART L FOR LOW VISCOSITY RANGE

ADAPTER
DESCRIPTION
CODE
APM
Small Sample Adapter with circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010
APM/B
Small Sample Adapter without circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010B
LCP Low Viscosity Adapter with circulation jacket with spindle
(The LCP and LCP/B accessories must be used with the LCP spindle).
V12013
LCP/B Low Viscosity Adapter without circulation jacket with spindle
(The LCP and LCP/B accessories must be used with the LCP spindle).
V12013B
 

MODEL SMART L FOR LOW VISCOSITY RANGE

SPINDLE
DESCRIPTION
CODE
SPINDLE
Set of special spindles (TL5, TL6, TL7) for APM and APM/B
(The APM and APM/B accessories must be used with the APM set of spindles).
V12600
SPINDLE
Set of 4 spindles for Model SMART L.
V12400
SPINDLE Spindle for LCP Low Viscosity Adapter
(This spindle must be used with the LCP or LCP/B Adapter).
V12800
 
 
Optional Accessories:

MODEL SMART R FOR MEDIUM VISCOSITY RANGE

ADAPTER
DESCRIPTION
CODE
APM
Small Sample Adapter with circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010
APM/B
Small Sample Adapter without circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010B
LCP Low Viscosity Adapter with circulation jacket with spindle
(The LCP and LCP/B accessories must be used with the LCP spindle).
V12013
LCP/B Low Viscosity Adapter without circulation jacket with spindle
(The LCP and LCP/B accessories must be used with the LCP spindle).
V12013B
HELDAL Helix Drive Unit, accessory for measuring non-flowing substances viscosity with spindles.
V12014
 

MODEL SMART R FOR MEDIUM VISCOSITY RANGE

SPINDLE
DESCRIPTION
CODE
SPINDLE
Set of special spindles (TR8, TR9, TR10, TR11) for APM and APM/B
(The APM and APM/B accessories must be used with the APM set of spindles).
V12700
SPINDLE
Set of 6 spindles for Model SMART R and Model SMART H.
V12500
SPINDLE Spindle for LCP Low Viscosity Adapter
(This spindle must be used with the LCP or LCP/B Adapter).
V12800
 
 
Optional Accessories:

MODEL SMART H FOR HIGH VISCOSITY RANGE

ADAPTER
DESCRIPTION
CODE
APM
Small Sample Adapter with circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010
APM/B
Small Sample Adapter without circulation jacket without spindles
(The APM and APM/B accessories must be used with the APM set of spindles).
V12010B
HELDAL Helix Drive Unit, accessory for measuring non-flowing substances viscosity with spindles.
V12014
 

MODEL SMART H FOR HIGH VISCOSITY RANGE

SPINDLE
DESCRIPTION
CODE
SPINDLE
Set of special spindles (TR8, TR9, TR10, TR11) for APM and APM/B
(The APM and APM/B accessories must be used with the APM set of spindles).
V12700
SPINDLE
Set of 6 spindles for Model SMART R and Model SMART H.
V12500
 
Standard Delivery:
Viscometer head, Stand for 3 levelling adjustment, Boss head, Standard spindles, Spindle protector, Spindle rack, Datalogger software in a CD, USB cable, Carrying case, Calibration certificate and Operational manual.
 
The Viscometers carry a 24 month warranty.
 
 
  Copyright © AUSGIANT LABORATORY EQUIPMENT PTY LTD. All rights reserved.
25, 43 Johnson Street, CHATSWOOD, NSW 2067 AUSTRALIA
TEL: +61 2 9411 2452    FAX: +61 2 9412 2048    E-MAIL:
info@ausgiant.net.au
Click AUSGIANT LABORATORY EQUIPMENT (WWW.AUSGIANT.NET.AU)