overview amino acid analyzer ion chromatography hpcpc applications hpcpc hpcpc accessories various detectors column ovens, degassers off. sample preparation on. sample preparation auto. sample preparation valves column selector online injector & sampler centrion ws autosampler encon p & t concentrator markelov autosampler est cobra autosampler hplc pumps syringe pumps flavourspec breathspec bp-ims gc-ims analytical ims uv-ims µims-odour ims-odour
 
 
 
 
ENCON PURGE & TRAP CONCENTRATOR         CHROMATOGRAPHY SYSTEM
 
 
Encon Purge and Trap Concentrator
 
We introduce an innovative concentrator that is equipped with a foam sensor, removable pathways, and on-trap injection ports to purge and trap. Now, with the innovative system, we bring you the most advanced purge and trap concentrator ever.
 
The concentrator has the following advantages:
 
- Reduce carryover and reruns by heating the sparge vessel during bake.
- Less downtime with foam sensor and overfill protection
- Modular Electronic Pressure Control for programmable flow rates and automated leak/pressure check capability.
- Moisture control during the purge cycle
- Fast cycle time with quick cool down and control of autosampler pre-time
- Fast and easy trap replacement
- Standard Touch screen interface and, superior chromatographic resolution
 
Lowest Carryover on the Market
The New Encon Evolution employs a patented mode where during the bake cycle of the concentrator, the sparging vessel is heated. The result is the lowest level of carryover on any concentrator today.
Percent Carry-over is listed below from the first blank run after a 200 ppb standard when the system is connected to a Centurion autosampler.
 
Data is even lower when run as a standalone concentrator:
 
Benzene ND
Toluene ND
Ethylbenzene ND
Xylene (m+p) ND
1,2,4-TCB

0.4%

Napthalene

0.4%

Hexachlorobutadiene

0.4%

1,2,3-TCB

0.4%

 
DPC - Desorption Pressure Control (Patented):
The Encon Evolution allows the user, after purge, to establish a set pressure within the trap.
Users can adjust this setting depending upon the column head pressure they are using to optimize peak shape.
 
Early Ready Signal:
Time is money. Unfortunately, there is time wasted in current purge and trap cycle time. Other purge and trap concentrators do not tell the autosampler to start processing the next sample until AFTER the purge and trap is ready.
The problem is there are several minutes that can be saved by starting the process of moving the sample to the sampling station, withdrawing the sample, beginning preheating if the sample is a soil sample etc. During this time the concentrator is just sitting there waiting.
 
The Encon Evolution can be programmed to send out a start signal while still in Bake mode to start the processing of the next sample early. This step alone can result in several more samples being run per day.
 
 
  Copyright © AUSGIANT LABORATORY EQUIPMENT PTY LTD. All rights reserved.
25, 43 Johnson Street, CHATSWOOD, NSW 2067 AUSTRALIA
TEL: +61 2 9411 2452    FAX: +61 2 9412 2048    E-MAIL: