overview atomic abso. spectrometer atomic abso. spectrometer atomic flu. spectrometer uv spectrophotometer microwave digestion microwave digestion vapour generator autosampler EPR spectrometer EPR spectrometer
 
 
 
 
ATOMIC FLUORESCENCE SPECTROMETER LUMINA 3300         ELEMENTAL ANALYSIS
 
 
The LUMINA 3300 Atomic Fluorescence Spectrometer provides elemental analysis solutions for sub trace detection of hydride-forming elements. The unique vapour generator provides enhanced sensitivities and reduced interferences for parts per trillion (ppt) detection of Mercury (Hg), Arsenic (As), Cadmium (Cd), Zinc (Zn), Bismuth (Bi), Selenium (Se), Tellurium (Te), Antimony (Sb), Tin (Sn), Germanium (Ge), and Lead (Pb).
 
The LUMINA 3300 Atomic Fluorescence Spectrometer is ideal for elemental analysis in various research sectors, including; environmental, agricultural, geological, metallurgical, pharmaceutical, clinical and petrochemical.
 
 
Atomic Fluorescence Spectrometer
 
FEATURES:
 
- Sub-trace level detection limits for Mercury and hydride forming elements
- Linear dynamic range of 10
- Covered optical design
- Dual-channel simultaneous measurement
- All-in-one mixing manifold, low dead volume, high efficiency, double gas/liquid separator design
- Automatic Ar-H2 flame ignition
- Integrated exhaust system
- Vapour/Hydride Generator
- Revolutionary Gas/Liquid Separator
- Reaction/Mixing Manifold
- Covered Optical Design
- Dual Channel Simultaneous Analyses
- Integrated Exhaust System
- User-Friendly, Windows-Based Software
- XYZ autosampler as an option
 
APPLICATIONS
Environmental (Hg, Pb, Cd, Zn, As, Sb, Se) Waste water
Drinking water
Soil and Sludge
Agriculture/ Food Safety (As, Hg, Pb, Sb and Se) Dairy, Wine and Meats
Food and Animal Byproducts
Cigarettes
Metallurgical (Ge, Hg, se, As in Sb, Se, Te in Cu) Rocks and Minerals
Steels and Alloys
Metals
Clinical (se, Pb, Hg, As, Sb, Bi, Ge) Blood and Urine
Tissue, Nail, Hair
Pharmaceutical (Hg, Pb, As, Se) Active Ingredients
Fillers
Petrochemical (Hg, Pb, Cd, As, Sn, Zn) Fuels, Lubricant, Crude Oil
 
DETECTION LIMIT
ELEMENT DETECTION LIMIT (ng/L) RSD %
As, Se, Pb, Bi, Sb, Te, Sn 10 ppt <1.0
Hg, Cd 1 ppt <1.0
Zn 2000 ppt <1.0
Ge 50 ppt <1.0
 
SAMPLE ATOMISATION
Atomiser Quartz tube furnace with automatic ignition of Ar-H2 diffusion flame reduces interference
Carrier Gas Argon
Protection Gas Argon
 
SAMPLE PREPARATION AND INTRODUCTION
Vapour/Hydride Generator
(Continuous Flow)
Continuous flow, peristaltic pump and syringe pump sequential injection system, high performance mixing section, gas-liquid separator for cold-vapour mercury determinations and hydride generation determinations of As, Se, Te, Bi, Sb, Sn, Pb, Ge, Zn, Cd, Hg.
Sequential Injection Sequential injection, complete control of sample injection which significantly improves detection limits and increases reliability.
It eleminates drifting completely.
It allows sample volume to be adjusted within a big range.
It has easy operation. It allows for on-line dilution
Peristaltic Pumps as an option A 6-channel pump with 2 adjustable pressure control clamps and programmable speed control
Exhaust System Exhaust system with filter efficiently decontaminates pollutants
Gas/liquid Separator High efficiency. Dual stage gas/liquid separator
Mixing Manifold Up to 5 levels of mixing and one level of draining
 
OPTICS
Optics Design Short focal length, non-dispersive, integrated optical design
Dual Channels Dual channels for sequential or simultaneous two-element analysis, using computer controlled, modulated, pulsed light sources
Light Sources Specially-designed high intensity Hollow Cathode Lamps (HCL) with 2 channel independent power supply, providing improved sensitivities and lower detection limits.
Detector High quantum efficiency, solar blind photo multiplier tube (PMT).
 
XYZ AUTOSAMPLER AS AN OPTION
Sample Introduction High sample capacity automated standard and sample introduction.
Sample Capacity Hosts a maximum of 192 standard cup/test tube sample racks.
Compatible with standard solvent extraction test tube.
ICP test tubes and custom made trays.
 
User-Friendly Window-Based Software:
This schematic software interface provides ease of operation instrument/autosampler control and data acquisition and analysis. Method development can be tested under single run when analysing one sample and batch run when analysing several samples and standards.
It enables real-time display of fluorescence intensity against time for both channels. It allows selection of either channel 1/channel 2 or both channels simultaneously. Reporting formats are LIMS compatible.
 
Multi-windows software layout:
- Method
- Autosampler
- Instrument Parameters
- Analytical Calibration Curve
- Reporting
 
Standard Methods Compliance:
The Lumina 3300 is compliant to various EPA method and it performs as per ASTM standards
 
EPA Method 245.7:
Mercury Determination in Water
 
EPA Method 7474:
Mercury Determination in Sediments
 
EPA Method 1631:
Mercury in water by Oxidation, Purge and Trap and Cold Vapour Atomic Fluorescence Spectrometry
 
Regulatory Standards and Certification
- RoHS and WEEE Compliant
- ISO 9001 certified
 
 
  Copyright © AUSGIANT LABORATORY EQUIPMENT PTY LTD. All rights reserved.
25, 43 Johnson Street, CHATSWOOD, NSW 2067 AUSTRALIA
TEL: +61 2 9411 2452    FAX: +61 2 9412 2048    E-MAIL:
info@ausgiant.net.au
Click AUSGIANT LABORATORY EQUIPMENT (WWW.AUSGIANT.NET.AU)