overview hplc pumps hplc pump model 500 model 500g model 501 performance data easy maintenance syringe pump fixed f. s. description fixed flow splitter fixed flow splitter fixed flow accessories ad. f. splitter description adjustable flow splitter adjustable flow splitter adjustable flow splitter adjustable f. accessories makeup flow splitter fixed makeup flow splitter adjustable m. f. splitter adjustable m. f. splitter adjustable performance makeup f. s. accessories
 
 
 
 
ADJUSTABLE MAKEUP FLOW SPLITTER         FLOW SPLITTER
 
 
(Variable Inlet Flow and Fixed Split Ratio)
 
The Adjustable Makeup-Flow Splitter Figure 18 can also be used with a constant inlet flow rate thereby allowing the user dynamic control over the split ratio and split flow rate. The Adjustable Makeup-Flow Splitters listed below are configured and calibrated assuming the Adjustable Makeup-Flow Splitter will be used to produce a wide split ratio range at the specified inlet flow rate. Each Adjustable Makeup- Flow Splitter ships with a calibration plot of inlet flow rate vs resistor rod setting required to produce the specified split flow within the defined range.
Please contact us for ordering information if your application requires a wider dynamic split ratio range and low flow.
 
These splitters will generate a pressure range from approximately 100 to 800psi over the split flow range specified. Although the split ratio will remain constant, pressure drop and outlet flow rates will change in proportion to changes in the inlet flow rate.
 
In order to maintain the pressure profile in the calibration plot, it is important to use these splitters at the inlet flow specified. Please specify the actual inlet flow rate with your order if it deviates substantially from the calibration flow rate listed below.
 
 
Adjustable Splitter: Fixed Inlet Flow and Variable Split Ratio
 

DESCRIPTONS

INLET FLOW
SPLIT FLOW
CALIBRATION FLOW & SPLIT RATIO
PART NUMBER

Makeup-Flow Splitter

1 - 5mL/ min. 5µL/ min. 5mL/min. = 1,000:1 690-PO01-05
Makeup-Flow Splitter 1 - 5mL/ min. 10µL/ min. 5mL/min. = 500:1 690-PO01-10
Makeup-Flow Splitter 1 - 5mL/ min. 20µL/ min. 5mL/min. = 250:1 690-PO01-20
Makeup-Flow Splitter 1 - 5mL/ min. 50µL/ min. 5mL/min. = 100:1 690-PO01-50
Makeup-Flow Splitter 10 - 20mL/ min. 5µL/ min. 30mL/min. = 6,000:1 690-PO10-05
Makeup-Flow Splitter 10 - 20mL/ min. 10µL/ min. 30mL/min. = 3,000:1 690-PO10-10
Makeup-Flow Splitter 10 - 20mL/ min. 20µL/ min. 30mL/min. = 1,500:1 690-PO10-20
Makeup-Flow Splitter 10 - 20mL/ min. 50µL/ min. 30mL/min. = 600:1 690-PO10-50
Makeup-Flow Splitter 50 - 150mL/ min. 5µL/ min. 100mL/min. = 20,000:1 690-PO50-05
Makeup-Flow Splitter 50 - 150mL/ min. 10µL/ min. 100mL/min. = 10,000:1 690-PO50-10
Makeup-Flow Splitter 50 - 150mL/ min. 20µL/ min. 100mL/min. = 5,000:1 690-PO50-20
Makeup-Flow Splitter 50 - 150mL/ min. 50µL/ min. 100mL/min. = 2,000:1 690-PO50-50
Makeup-Flow Splitter Custom Custom - 690-POCS-CS
 
 