overview cell biology workstation cell biology workstation stem cell workstation microbio. workstation bulk tray freeze dryer bulk tray freeze dryer bench top freeze dryer chemical free freeze dryer freeze dryer combi freeze dryer upright freeze dryer freeze dryer accessory laboratory freeze dryer vacuum concentrator vacuum concentrator ir concentrator gas blowing concentrator mini centrifuge high speed centrifuge micro speed centrifuge large capacity centrifuge multi purpose centrifuge
 
 
 
 
freeze dryer          BIOLOGYICAL LABORATORY
 
 
CLEANVAC 8, 12, 8S & 12S
 
The CleanVac system is a lab scale freeze dryer using the lyophilisation phenomena.
The cylindrical shape transparent acryl chamber is used for dry chamber and stainless steel petri dishes are used with rack system to dry the frozen specimen.
The CleanVac system has a very large size cold trap that can be used for pre-freezer and it does not need the exclusive pre-freezer system.
The microprocessor governs the whole system process and it monitors the temperature with pt-100 temperature sensor and vacuum level with pirani gauge.
The microprocessor automatically decides the leak condition from the vacuum level and gives a warning to the LCD display in order to prevent the damage of vacuum pump by overflow of the molten specimen. Furthermore, the microprocessor periodically stops the vacuum level to find out the end of freeze drying procedures.
 
FEATURES:
 
Lyophilisation is the most effective way to preserve living cells, whole blood, vaccines, biological specimens, vegetable, meat, fish and general food.
The powerful compressor with CFC-free refrigeration system can decrease the temperature of the cold trap to -85C.
The detachable front panel provides easy access to refrigeration system and pump for maintenance.
High capacity refrigeration system ensures rapid cooling.
The vacuum pressure is precisely measured by Pirani vacuum gauge.
The microprocessor controls the whole system and all the parameters are displayed in the LCD display.
Self diagnosis algorithm for checking the end of the freeze drying pressure:
Stop the vacuum pump for each hour and check the pressure change, if the value of pressure automatically displays the end of the drying procedure in the LCD panel.
The heater plate can be installed to the rack for Petri dishes to accelerate the drying speed.
LCD display shows the vacuum pressure, chamber and trap temperatures, and the other processing parameters.
 

COLD TRAP TEMPERATURE: -45 C

MODELS
CLEANVAC 8S
CLEANVAC 12S

Catalogue Number

PV1M1AF09
PV1M1AF12
Trap Chamber
310 D X 250 H mm
310 D X 300 H mm
Compressor
1 HP
3/4 HP
Maximum Capacity
8 liter
12 liter
Dimension
740 W X 600 D X965 H mm
Power Consumption
240V, 50Hz, 1.5KW
 

COLD TRAP TEMPERATURE: -85 C

MODELS
CLEANVAC 8
CLEANVAC 12

Catalogue Number

PV1M1AF08
PV1M1AF11
Trap Chamber
310 D X 250 H mm
310 D X 300 H mm
Compressor
1 HP X 2
3/4 HP X 2
Maximum Capacity
8 liter
12 liter
Dimension
740 W X 600 D X965 H mm
Power Consumption
240V, 50Hz, 1.5KW
 

DIGITAL CONTROLLER

Pirani Gauge

Minimum 0.005 TORR, Maximum Ambient Pressure, Semi Log Scale
Resolution: 0.5 for each decade
Temperature Sensor Pt 100 Sensor, -85 C TO 40 C, 1 C Step Resolution
 
 